- 5 -- 4 -
Relay status Current mode
Adjustment buttons
Selection of
the operating mode
or configuration
(installer)
Set-point
temperature or
temperature
measured per
MINOR 11
Auto
Heating
demand
mode
Off
Comfort
Economy
Frost
Protection
15 mm 33 mm 80 mm
80 mm
Part fitting into the
flush-mounted box
2.1 The pilot wire principale (CALYBOX standard)
The pilot wire principle enables the required
operating mode to be selected from a programmer
(CALYBOX range, Driver range, etc.).
The MINOR 11 thermostat thus controls the
corresponding temperature.
Order sent by
the programmer
Corresponding temperature
controlled by the thermostat
Comfort
Comfort- 1°C
Comfort setting (5°C to +30°C)
Comfort - 1°C setting
Comfort- 2°C Comfort - 2°C setting
Economy
Economy setting (5°C to +30°C)
Frost Protection
Frost protection Frost protection can
be set from 5°C to 15°C (7°C by default)
Off Heating switched off
2- Presentation
• Suitable for underfloor heating or radiant ceiling
heating
• Permanent regulation (proportional integral)
• Simple control system (pilot wire principle)
• Up to 6 operating modes (GIFAM standard)